Community Exposure Reference · CIH Ch.8

CIH Community Exposure Reference

Chapter 8 in one order that follows the pollutant: where it comes from, how it travels, what reaches people, how it is measured, and how it is cleaned or contained, ending with spill response and a self-test. Each table marks the fact an exam question most often leans on in red.

How to use this page

BGC’s Community Exposure subject area covers air pollution, air-cleaning technology, ambient air quality, emission source sampling, atmospheric dispersion, ambient monitoring, health and environmental effects, and emergency planning and responseBGC. The sections below run in the order a real problem unfolds, so each one gives the next its inputs.

01 Where Pollutants Come From

Start here: you cannot judge dispersion or control until you know whether a pollutant is emitted or formed.

Why ambient limits are stricter than TLVs. A TLV assumes a healthy adult worker exposed about 40 hours a week. Ambient standards protect the whole public, including children, older people and people with asthma, breathing the air all 168 hours of the week. EPA’s national standards come in two kinds: primary standards protect health, and secondary standards protect welfare (visibility, crops, animals, buildings)EPA.

Source splitMeaningExamples
NaturalReleased without human activityVolcanoes (SO2, ash), wildfires, wind-blown dust, sea spray, pollen, VOCs from vegetation
AnthropogenicReleased by human activity; dominates in industrial areas, though the share differs by pollutantPower plants, industry, heating, agriculture
Mobile (a kind of anthropogenic)Vehicles and enginesThe largest source of outdoor carbon monoxide: incomplete combustion in enginesEPA

The pollutants below are the criteria pollutants regulators trackEPA plus the toxic and organic species that come up in CIH questions. Nitrogen oxides and VOCs are primary pollutants, but they are also the precursors of the secondary ones.

TypeMeaningExamplesCIH study cue
PrimaryEmitted directly from an identifiable source (tailpipe, stack, fire, dust from soil).Carbon monoxide (incomplete combustion); sulfur dioxide (coal or oil burning); NO and NO2 (high-temperature combustion); particulate matter and coarse dust; lead; VOCs such as benzene and formaldehyde; toxic metals (mercury, cadmium, arsenic).If you can point at the source, it is primary.
SecondaryNot emitted; formed in the air when primaries react with sunlight, moisture and each other.Ground-level ozone; photochemical smog (ozone, PANs, aldehydes); acid deposition (sulfuric and nitric acids from SO2 and NOx); secondary fine particles (ammonium sulfate and nitrate); secondary organic aerosols; nitric acid vapor; part of ambient formaldehyde.If the question says it forms in the atmosphere, on hot sunny days, or by reaction, it is secondary.
Photochemical smog
VOCs + NOx + sunlight → ozone + PANs + aldehydesEPA. A peak in the mid-to-late afternoon on a hot, sunny day points to ozone or smog, not to a morning traffic peak.
Hydroxyl radical (OH)
The atmosphere’s cleaning agent: it oxidizes primary pollutants out of the air, but the products can themselves be hazards (acids, secondary particles).
Indoor secondary pollution
Ozone from air purifiers or copiers reacts with terpenes from citrus or pine cleaners to form formaldehyde and ultrafine particles indoors.
Precursor vs product
Cut NOx and VOC emissions to reduce ozone; cut SO2 and NOx to reduce acid deposition and secondary fine particles.

02 How Pollutants Travel

Atmospheric stability decides the plume shape, and the plume shape decides who is exposed at ground level.

Stability comes from comparing the real temperature profile with the dry adiabatic lapse rate, the rate a rising parcel of dry air cools: 9.8 °C per km (5.5 °F per 1,000 ft)NWS.

Real air cools with height…NameStabilityPasquill classMixing
Faster than 9.8 °C/kmSuperadiabaticUnstableA–C (strong sun, light wind)A lifted parcel keeps rising: strong vertical mixing
At about 9.8 °C/kmAdiabaticNeutralD (overcast or windy)Parcel neither rises nor sinks on its own
Slower than 9.8 °C/kmSubadiabaticStableE–F (clear night, light wind)Vertical motion is damped
Warms with heightInversionVery stableFA lid: pollutants below it are trapped
PlumeAtmosphereWhat it looks likeGround-level effectExam cue
LoopingVery unstable (strong solar heating, convection)Wavy, looping up and downHighly variable; can touch the ground in burstsSunny, turbulent, large vertical swings.
ConingNeutral (moderate wind, overcast)Cone spreading equally in both directionsFairly predictableNeutral; equal horizontal and vertical spread.
FanningVery stable (strong inversion)Thin, flat ribbon; almost no vertical spreadUsually low near the stack; can matter downwind or at terrain and tall buildingsInversion; horizontal spread, little or no vertical spread.
LoftingStable below the plume, unstable aboveSpreads upward, little downward mixingLowest ground-level concentrationStable below, unstable above; plume goes up.
FumigationUnstable below the plume, stable (inversion) abovePushed down toward the groundHighest ground-level concentrationInversion lid above; downward mixing; plume reaches the ground.
Read the stability first
Unstable → looping. Neutral → coning. Stable → fanning. Then the two special layered cases: stable above and unstable below → fumigation (down); stable below and unstable above → lofting (up).
The key pair
Fumigation = down = high ground concentration. Lofting = up = low ground concentration.
Gaussian plume model
The standard regulatory model spreads the plume as a bell curve sideways and vertically, with spreads set by stability class and distance. Ground concentration rises with the emission rate and falls with wind speed and with effective stack height = physical height + plume rise from the gas’s buoyancy and momentumEPA.
Terrain still matters
A fanning plume is thin and flat, so a hill, valley wall or tall building it meets can bring it to the ground. Do not treat “low near ground” as “safe”.

03 What Reaches the Community

Two calculation habits: dilute the emission, and correct the unit conversion for the actual air.

Dilution factor
Cambient = Cemission ÷ dilution factor. Worked example: stack 350 mg/m3, dilution factor 5,000 at the nearest homes → 350 ÷ 5,000 = 0.07 mg/m3. Keep units unchanged; a dilution factor is a ratio, not a removal efficiency.
mg/m3 to ppm depends on the air
ppm = (mg/m3) × (molar volume) ÷ (molecular weight), and molar volume scales with T/P. Hotter air or lower pressure gives a larger molar volume, so the same mass concentration converts to a higher ppm. Use the reference conditions the question states (commonly 25 °C or 20 °C and 29.92 in Hg).
Actual vs referenceEffect on molar volumeCalculated ppm
Higher temperatureLargerHigher
Lower pressureLargerHigher
Lower temperature or higher pressureSmallerLower

Two nearby formulas from the ventilation chapters also appear in community questions. Well-mixed room: V·dC/dt = G + Q·Cin − Q·C (plus any removal term), so generation rate, airflow, supply-air concentration and room volume matter, while air density is not a variable. Simplified outdoor air: a 20 cfm-per-person rule of thumb is a shortcut; ASHRAE 62.1 actually adds a people component (Rp) and an area component (Ra).

04 How to Measure It

Match the pollutant to its sampler and its analytical method.

These are the classic methods taught for the exam. Current regulatory monitoring uses EPA-designated reference or equivalent methodsEPA, many of them automated, so treat this table as recognition practice.

PollutantCollection or measurementAnalytical method
Total suspended particulate (TSP)High-volume sampler with filterGravimetric: mass gain on the filter
LeadHigh-volume sampler with filterAcid extraction, then atomic absorption
Sulfur dioxideBubbler or impinger with absorbing solutionWest-Gaeke colorimetric method
OzoneReaction chamberChemiluminescence (light from the ozone reaction, read by a photomultiplier)
Carbon monoxideGas absorption cellNondispersive infrared (NDIR) absorption
HydrocarbonsGas intake and detectorFlame ionization detector, often with gas chromatography
Nitrogen dioxideBubbler (colorimetric) or reaction chamberSaltzman colorimetric method, or chemiluminescence (NO reacts with ozone; NO2 is measured after conversion to NO)

05 Stack Sampling and Isokinetic Flow

A stack sample is only representative if the probe takes gas at the speed the stack is moving.

Stack testingEPA aims for isokinetic sampling: the probe draws gas at the same velocity as the gas in the stack (Vs = Vd). Coarse particles have inertia and cannot follow streamlines that bend around the probe, so a velocity mismatch changes which particles get in.

ConditionNameWhat the probe doesParticle biasReading
Vs = VdIsokineticTakes a true slice of the stack gasRepresentativeAccurate
Vs < VdSub-isokineticDraws gas slower than the stack movesCoarse particles over-sampledConcentration reads high
Vs > VdSuper-isokineticDraws gas faster than the stack movesCoarse particles under-sampled; fines over-representedConcentration reads low
Memory trick
Low probe velocity → coarse over-sampled. High probe velocity → coarse missed. Equal velocity → representative.
Watch the direction
Coarse particles are what make particulate mass large, so the bias in mass concentration follows the coarse fraction: more coarse in the sample means a higher reading, fewer means a lower one.

06 Cleaning the Emission

Pick the device from particle size and physical state first; then check its weak spot.

DeviceTypical target sizeHow it worksBest forWeak spotPressure drop (typical)
Cyclone (dry centrifugal)Coarse, roughly 5–15 µm and largerSpinning vortex throws heavy particles to the wall and into a hopperCoarse dust: woodworking, quarry, cement handling; pre-cleaner upstream of finer devicesEfficiency drops below about 10 µm; fails on fume and smoke; depends on design flow; abrasive dust wears the casingLow to moderate (about 2–6 in. w.g.)
Venturi scrubber (high-energy wet)Fine and submicron, about 0.1–1 µmGas accelerated through a narrow throat; injected water atomizes into droplets that capture particlesMetal fume, smoke and mist; hot, sticky, flammable or explosive streamsVery high energy use; produces wastewater or slurry; corrosion; needs a mist eliminatorVery high (30–100+ in. w.g.)
Baghouse (fabric filter)About 0.1 µm up to 20+ µmDirty air passes through fabric bags that trap dry dustDry dusts: grain, concrete and asphalt batching, powdersCondensation blinds the bags; hot gas limits; combustible dust needs explosion protection; sticky or wet streamsModerate (about 3–6 in. w.g.)
Electrostatic precipitator (ESP)Ultrafine, about 0.01–1 µmHigh-voltage wires charge particles, which stick to grounded plates and are rapped offHuge airflows with smoke and ash: power plants, incinerators, steelDust resistivity (too low: particles re-enter the air; too high: back corona); ozone and spark risk with explosive dust or gas; high capital cost and footprintLow (about 0.5–2 in. w.g.)

Ranges and pressure drops are typical teaching valuesCCOHS; real equipment varies with design and operating conditions.

Fast device chooser
Coarse dust → cyclone. Dry dust → baghouse. Fume, mist, sticky or flammable stream → venturi scrubber. Ultrafine smoke and ash at huge flow → ESP.
Baghouse gauge units
Baghouse pressure drop is read in inches of water gauge, not inches of mercury (1 in. Hg ≈ 13.6 in. H2O). It rises with dust cake, filter media, air-to-cloth ratio, and gas temperature and moisture.
Scrubbers move the problem
A wet scrubber turns an air problem into a liquid waste problem: the slurry needs settling or treatment before discharge or recirculation.
Combustible dust
Fine flour, wood, or metal powder can explode. ESPs add a spark risk; baghouses need vents, grounding and spark control; a wet scrubber has no ignition source.

07 Water Pollution and Hazardous Waste

The same source-to-control logic, applied to what goes into water and what goes to disposal.

TopicKey ideaCIH study cue
Point vs nonpoint sourceA point source is a discrete conveyance such as a pipe, ditch or channel (concentrated animal feeding operations count too). Nonpoint pollution is diffuse runoff from farms, streets and lawnsPoint sources discharging to US waters need an NPDES permit under the Clean Water ActEPA
Biochemical oxygen demand (BOD)Oxygen that microbes use to break down organic matter in water, usually measured over 5 days (BOD5)High BOD → low dissolved oxygen → fish kills. Sewage and food-processing waste are high-BOD
Wastewater treatmentPrimary: physical settling. Secondary: biological treatment that lowers BOD. Tertiary: nutrient removal and polishing; then disinfectionPrimary = physical, secondary = biological
RCRA hazardous wasteListed: F (non-specific sources, such as spent solvents), K (specific industries), P (acutely hazardous discarded chemicals), U (other discarded chemicals). Characteristic: ignitable, corrosive, reactive or toxicEPARCRA manages waste “cradle to grave” from generation to disposal. Characteristics: I-C-R-T
CERCLA (Superfund)Passed in 1980 to clean up contaminated sites; responsible parties pay, and the fund covers sites with no viable responsible partyEPARCRA = today’s waste. CERCLA = yesterday’s contamination
P is poison
P-listed wastes are the acutely hazardous discarded chemicals; U-listed are the other discarded commercial chemicals. Both apply only to unused chemical product.
Controls move pollution
A scrubber moves air pollution into water; a baghouse moves it into solid waste. The community question is where it goes next.

08 When It Goes Wrong: Spills and Incident Command

Community emergencies reuse the same ideas: dispersion, terrain, and a fixed command structure.

Reasoning through a release

Ask these first
1. Is the material heavier or lighter than air? 2. Is it a toxic inhalation hazard? 3. What are wind and stability doing? 4. How far, and how high or low, is the population from the source? 5. Does the terrain channel the cloud?
Terrain and density
A heavier-than-air gas such as chlorine sinks and follows low ground, so valleys and river cuts collect it. A community well above the release is in a different position from one downhill, but confirm it with the ERG distances and current conditions rather than assuming.
Calm, sunny air
Calm wind means little transport; strong sun means unstable air that mixes upward. Both change the answer compared with a still night under an inversion, which holds a cloud near the ground.

Emergency exposure guidelines

TLVs and PELs are built for repeated working-day exposure. A one-time release to the public needs limits built for a single short exposure.

LevelERPG (AIHA): up to 1 hourNOAAAEGL (EPA): 10 min, 30 min, 1 h, 4 h and 8 hEPA
1No more than mild, transient effects, or a clearly objectionable odorNotable discomfort or irritation; transient and non-disabling
2No irreversible or serious effects, and no symptoms that would stop people protecting themselvesIrreversible or serious long-lasting effects, or an impaired ability to escape
3No life-threatening effectsLife-threatening effects or death
Below vs above
An ERPG is the concentration below which nearly everyone is fine for 1 hour. An AEGL is the concentration above which the general public, including susceptible people, could suffer that level of effect.
Level 2 is the planning line
Level 2 marks where people may lose the ability to escape, so it is the usual line for evacuation and shelter-in-place zones. Dispersion software draws yellow, orange and red zones for levels 1, 2 and 3.

Emergency Response Guidebook (ERG)

The ERGPHMSA is a first-response tool for the opening phase of a transportation incident. Its colour-coded sections work as a lookup chain that ends at the action pages.

SectionRoleWhat you find
White (front)SetupHow to use the book, shipping papers, placards, rail and trailer identification
YellowLook up by numberFour-digit UN/NA ID numbers in order, each pointing to a guide
BlueLook up by nameMaterial names in alphabetical order, each pointing to a guide
OrangeThe action pagesThe numbered Safety Guides (numbered 111–172 in recent editions): potential hazards, public safety, and emergency response for fire, spill or leak, and first aid
GreenDistancesInitial isolation and protective action distances for toxic inhalation hazard materials and water-reactive materials
White (back)Specialized guidanceContacts, pipeline safety, improvised explosive and CBRN response information

Each Safety Guide opens with the greater danger first, health or fire and explosion; the public safety block gives isolation and protective equipment; the response block gives the tactical steps.

Incident Command System (ICS)

ICSFEMA is a standard, modular, top-down structure so responders from many agencies can work together.

LevelRoleJob
CommandIncident CommanderOverall responsibility: sets objectives and directs tactics
Command StaffSafety OfficerMonitors hazards; may stop or alter unsafe actions
Command StaffPublic Information OfficerSingle point of contact for media and the public
Command StaffLiaison OfficerCoordinates with assisting outside agencies
General StaffOperationsRuns the tactical response on scene
General StaffPlanningGathers information, tracks resources, prepares the incident action plan
General StaffLogisticsFacilities, transport, supplies, food, medical and communications
General StaffFinance/AdministrationCosts, claims, procurement, records
General Staff (optional)Intelligence/InvestigationsUsed for criminal, terrorist or complex incidents
Span of control
A supervisor should manage about 3 to 7 people or units, with 5 being ideal. When a supervisor would exceed that, the structure splits.
Splitting Operations
Division = by geography. Group = by function. Branch = added when span of control is exceeded or work is specialized (for example a hazmat or medical branch).
Resource units
Single resource = one person or piece of equipment. Task force = mixed resources for one mission. Strike team = same kind and number of resources with one leader.

09 Self-Test

Original scenarios. Cover the answer, decide, then open it.

1A coastal city’s ozone monitor peaks at 3 p.m. on a hot, cloudless day, but traffic volume peaks at 8 a.m. Is ozone a primary or secondary pollutant, and why does the peak come late?

Secondary. Ozone is not emitted; it forms from NOx and VOCs in sunlight, so it builds through the day and peaks in the afternoon.

2On a clear, calm night with a strong ground-level inversion, a stack plume is a thin flat ribbon that barely spreads vertically. Name the plume and say what to watch for near the ground.

Fanning (very stable). Concentrations are usually low near the stack, but terrain or tall buildings can bring the ribbon down, so check downwind obstacles.

3Just after sunrise, the ground warms under an inversion that still sits above a smelter stack. The plume is pushed down. Which plume, and what is the ground-level result?

Fumigation: unstable below, stable above. This gives the highest ground-level concentrations.

4A stack emits 480 mg/m3 and the dilution factor to the nearest homes is 12,000. What concentration reaches the homes?

480 ÷ 12,000 = 0.04 mg/m3.

5A stack tester pulls gas through the probe more slowly than the gas moves in the stack. Which particles are favored, and which way does the reading err?

Sub-isokinetic: coarse particles are over-sampled and the concentration reads high.

6A foundry vents hot, sticky, submicron metal fume with some mist. Which device is the natural choice, and why not a cyclone or a baghouse?

A venturi scrubber. A cyclone is ineffective on submicron fume, and a baghouse is blinded by sticky, wet or hot streams.

7A plant vents very fine combustible organic dust plus toxic fume beyond the fence line. Which two common devices would you rule out first?

The ESP, because its electrical discharge is an ignition source for combustible dust, and the cyclone, which cannot capture fines. That leaves a baghouse with explosion protection or a wet scrubber; the scrubber has no ignition source and also captures fume.

8An air sample is converted from mg/m3 to ppm at 95 °F and 29.70 in Hg, compared with reference conditions of 68 °F and 29.92 in Hg. Is the calculated ppm higher or lower than expected?

Higher: the air is hotter and at lower pressure, so the molar volume is larger and the same mass concentration gives a higher ppm.

9Morning air cools at 12 °C per km of height. Is the atmosphere stable or unstable, and what does that do to a plume?

Unstable (superadiabatic: faster than 9.8 °C/km). Strong vertical mixing gives a looping plume.

10A plant raises its stack from 30 m to 60 m with the same emissions. What happens to the maximum ground-level concentration, and why?

It falls: a higher effective stack height gives the plume more distance to spread before it reaches the ground.

11A drum of unused, off-spec pesticide listed as acutely hazardous must be discarded. Which RCRA list applies?

The P-list: acutely hazardous, unused commercial chemical product.

12An emergency planner must draw the zone where the public could lose the ability to escape during a 1-hour chlorine release. Which guideline level?

ERPG-2 (or the 60-minute AEGL-2).

13Eight responders report directly to one supervisor at a spill. What does ICS suggest?

The span of control is exceeded (3–7, ideally 5), so create a subordinate level such as a division, group or branch.

These are original practice scenarios written for this page. They are not BGC questions and do not predict exam content.

Scope from BGC’s subject-area definitions; supporting facts from EPA, CCOHS, PHMSA and FEMA pages listed on the references page (links checked September 24, 2026). Numeric ranges and pressure drops are typical teaching values. SPEP is not affiliated with BGC.